---
title: INGEGRID™ STATCOM for mining
description: INGEGRID™ STATCOM solutions for mining ensure grid stability, improve power quality, and optimize operational performance through dynamic reactive power compensation.
---

<https://sites.ingeteam.com/ingegrid-statcom>

# INGEGRID™ STATCOM for mining applications

Dynamic reactive power compensation for demanding mining grids

[![IMG\_2875](https://sites.ingeteam.com/hubfs/IMG_2875.jpg) Power quality for mining STATCOM solutions for electrical stability and grid compliance](https://sites.ingeteam.com/ingegrid-statcom#sectors)

[![2686-ÔÇó-8BITS](https://sites.ingeteam.com/hubfs/Producto%20(Fotos)/INGEDRIVE/2686-%C3%94%C3%87%C3%B3-8BITS.png) Our solutions LV and MV power solutions](https://sites.ingeteam.com/ingegrid-statcom#products)

[![20180325\_164915](https://sites.ingeteam.com/hubfs/20180325_164915.jpg) Retrofit solutions Fit to existing installations](https://sites.ingeteam.com/ingegrid-statcom#retrofit)

![IMG\_2875](https://sites.ingeteam.com/hubfs/IMG_2875.jpg)

## Power quality for mining

INGEGRID™ STATCOM by Ingeteam is a **dynamic reactive power compensation solution based on power electronics,** designed to improve voltage stability and power quality in mining electrical systems.

- Dynamic reactive power compensation
- Fast and accurate voltage control
- Improved power quality
- Compliance with grid codes and utility requirements

[Get a quote!](https://sites.ingeteam.com/ingegrid-statcom#contact)

## Water Cooled Drives

![INGEDRIVE\_LV800](https://sites.ingeteam.com/hubfs/Landings/MMM/Marine%20Sector/PRODUCTS/INGEDRIVE_LV800.webp)

### INGEDRIVE™ LV800

- **Power:**  1,000 kW - 9,000 kW
- **Voltage:**  380V / 690 V

[Get a quote!](https://sites.ingeteam.com/ingegrid-statcom#contact)

![IMG\_1632\_Archivo\_ingedrive-mv300-2](https://sites.ingeteam.com/hubfs/Landings/MMM/INGEDRIVE/IMG_1632_Archivo_ingedrive-mv300-2.jpg)

### INGEDRIVE™ MV100

- **Power:**  2,500 kW - 12,700 kW
- **Voltage:**  3,300 V /4,160V

[Get a quote!](https://sites.ingeteam.com/ingegrid-statcom#contact)

![IMG\_467\_Archivo\_mv500-ingedrive7403-97-98bits](https://sites.ingeteam.com/hubfs/Landings/MMM/INGEDRIVE/IMG_467_Archivo_mv500-ingedrive7403-97-98bits.jpg)

### INGEDRIVE™ MV500

- **Power:**  10,000 kW - 40,000 kW
- **Voltage:**  3,300 V

[Get a quote!](https://sites.ingeteam.com/ingegrid-statcom#contact)

![IMG\_2095\_Archivo\_mv900-1](https://sites.ingeteam.com/hubfs/Landings/MMM/INGEDRIVE/IMG_2095_Archivo_mv900-1.png)

### INGEDRIVE™ MV900

- **Power:**  4,000 kW - 44,000 kW
- **Voltage:**  6,600 V

[Get a quote!](https://sites.ingeteam.com/ingegrid-statcom#contact)

## INGEGRID™ STATCOM

![LV800\_VISTA3](https://sites.ingeteam.com/hubfs/Producto%20(Fotos)/INGEDRIVE/Variadores_Frecuencia/2000x1818/Vista3_Lateral%20izquierdo/LV800_VISTA3.png)

### INGEGRID™ LV800

- **Water cooled**
- **Reactive power:** 4 MVAr - 9 MVAr
- **Voltage:** up to 600 V

[More info](https://sites.ingeteam.com/hubfs/Marketing%20Files%20(pdfs)/MMM%20Files/DyA/INGEDRIVE/Flyers/Producto%20INGEDRIVE/%5BINGEDRIVE_LV800%5D_TF00IPT_MI01_.pdf?hsLang=en)

![MV100W\_VISTA3](https://sites.ingeteam.com/hubfs/Producto%20(Fotos)/INGEDRIVE/Variadores_Frecuencia/880x800/Vista3_lateral%20izquierdo/MV100W_VISTA3.png)

### INGEGRID™ MV100

- **Air cooled**
- **Reactive power:** 7 MVAr - 28 MVAr
- **Voltage:** up to 3,6 kV

[More info](https://sites.ingeteam.com/hubfs/Marketing%20Files%20(pdfs)/MMM%20Files/DyA/INGEDRIVE/Flyers/Producto%20INGEDRIVE/%5BINGEDRIVE_MV100%5D_FY07IPTT01_A.pdf?hsLang=en)

![MV100A\_VISTA3](https://sites.ingeteam.com/hubfs/Producto%20(Fotos)/INGEDRIVE/Variadores_Frecuencia/880x800/Vista3_lateral%20izquierdo/MV100A_VISTA3.png)

### INGEGRID™ MV100

- **Water cooled**
- **Reactive power:** 10 MVAr -50 MVAr
- **Voltage:** up to 2,7 kV

[More info](https://sites.ingeteam.com/hubfs/ingedrive-mv100-fy07iptt01-a.pdf?hsLang=en)

![MV900\_VISTA3](https://sites.ingeteam.com/hubfs/Producto%20(Fotos)/INGEDRIVE/Variadores_Frecuencia/2000x1818/Vista3_Lateral%20izquierdo/MV900_VISTA3.png)

### INGEGRID™ MV900

- **Water cooled**
- **Reactive power:** 30 MVAr - 100 MVAr
- **Voltage:** up to 5,5 kV

[More info](https://sites.ingeteam.com/hubfs/Marketing%20Files%20(pdfs)/MMM%20Files/DyA/INGEDRIVE/Flyers/FY67IPTT01D_%5BProduct_range_table_Flyer%5D.pdf?hsLang=en)

## Air Cooled Drives

![INGEDRIVE™ LV200](https://sites.ingeteam.com/hubfs/Landings/landing-sector-producto/trigger-2b.jpg)

### INGEDRIVE™ LV200

- **Power:**  300 kW - 1,400 kW
- **Voltage:**  380 V / 690 V

[Get a quote!](https://sites.ingeteam.com/ingegrid-statcom#contact)

![INGEDRIVE™ MV100](https://sites.ingeteam.com/hubfs/Landings/landing-sector-producto/trigger-2b.jpg)

### INGEDRIVE™ MV100

- **Power:**  800 kW - 4,800 kW
- **Voltage:**  3,300 V /4,160V

[Get a quote!](https://sites.ingeteam.com/ingegrid-statcom#contact)

![INGEDRIVE™ MV300](https://sites.ingeteam.com/hubfs/Landings/landing-sector-producto/trigger-2b.jpg)

### INGEDRIVE™ MV300

- **Power:**  250 kW - 1,250 kW
- **Voltage:**  4,160 V / 6,600 V

[Get a quote!](https://sites.ingeteam.com/ingegrid-statcom#contact)

![INGEDRIVE™ MV700](https://sites.ingeteam.com/hubfs/Landings/landing-sector-producto/trigger-2b.jpg)

### INGEDRIVE™ MV700

- **Power:**  1,700 kW - 7,400 kW
- **Voltage:**  6,000 V / 6,900 V

[Get a quote!](https://sites.ingeteam.com/ingegrid-statcom#contact)

![20180325\_164915](https://sites.ingeteam.com/hubfs/20180325_164915.jpg)

## Solve retrofit challenges

We deliver **retrofit solutions** to **upgrade or extend reactive power compensation** in **existing mining facilities**, adapting systems to new grid requirements without replacing the main infrastructure.

- Integration with existing electrical systems
- Upgrade of obsolete equipment
- Adaptation to new grid requirements
- Optimised investment compared to new installations

[Get a quote!](https://sites.ingeteam.com/ingegrid-statcom#contact)

![VFD for Soft starting LNG compressor](https://sites.ingeteam.com/hubfs/Sector%20(Fotos)/OIL%20AND%20GAS/AdobeStock_102289052.jpeg)

Case Study

## XX

XX

[Download the case study](https://sites.ingeteam.com/ingegrid-statcom#inline-case)

## FAQs

What does an STATCOM deliver in a mining project?

**A Static Synchronous Compensator (STATCOM)** delivers **dynamic reactive power compensation**, fast voltage regulation, and advanced power quality control. By **stabilising the electrical network,** it **protects mining operations** from voltage fluctuations and disturbances, ensuring reliable and continuous production.

How does a STATCOM regulate voltage in mining applications?

A STATCOM regulates voltage by dynamically **injecting or absorbing reactive power through power electronic converters.**

Its fast response capability **allows real-time compensation** of voltage variations caused by load changes, grid disturbances, or weak network conditions, ensuring stable operation under demanding mining environments.

How does INGEGRID™ improve power quality in mining facilities?

**INGEGRID™ STATCOM** improves power quality by **reducing voltage flicker, mitigating rapid voltage dips and swells, and stabilising the network** during dynamic load variations. This helps protect sensitive equipment, extend asset lifetime, and minimise unplanned downtime.

Is our solution suitable for retrofit projects?

Yes, INGEGRID™ STATCOM can u**pgrade, replace, or expand existing reactive power compensation systems** to meet new technical, operational, or regulatory requirements.

Ingeteam engineers customised solutions adapted to each site, allowing modernisation without replacing the main electrical infrastructure.

![Banner LinkedIn Campaña - PERSONAL-1](https://sites.ingeteam.com/hubfs/Banner%20LinkedIn%20Campa%C3%B1a%20-%20PERSONAL-1.jpg)

## About us

**Half a Century of Innovation**

A multinational company with over 3,800 professionals and presence in 15 countries,  that has remained true to its roots as a family-owned business.

Today, we are a key player in the electrification of society, positioning ourselves at the forefront of technology in the sectors in which we operate.

Our focus has always been clear: technology, technology, and more technology. Investment in R&D has been and will continue to be essential to maintaining our leadership.

 

## Let's talk about the future!

[Contact now!](https://sites.ingeteam.com/ingegrid-statcom#contact)

![2013\_4868](https://sites.ingeteam.com/hubfs/Landings/MMM/SHORE/2013_4868.jpg)

## Subscribe to our newsletter!

<https://sites.ingeteam.com/ingegrid-statcom>

Let’s stay in touch

- [Instagram](https://www.instagram.com/ingeteam/)
- [Twitter](https://twitter.com/ingeteam)
- [Youtube](https://www.youtube.com/user/IngeteamGroup)
- [Linkedin](https://es.linkedin.com/company/ingeteam-s-a)

- [Channel for reporting non-compliance and irregularities](https://www.ingeteam.com/en-us/aboutus/ethicsandcompliance.aspx)

- [Legal notice](https://www.ingeteam.com/en-us/legal/legalnotice.aspx)
- [Privacy policy](https://www.ingeteam.com/en-us/legal/privacypolicy.aspx)
- [Cookie policy](https://www.ingeteam.com/en-us/legal/cookiepolicy.aspx)

Copyright © Ingeteam 2025. All rights reserved.

<https://api.whatsapp.com/send/?phone=14143090584&text=Hello%2C+I%27m+interested+in+your+EV+chargers.&type=phone_number&app_absent=0>

Request your direct discount!

Download

Download

Download the case study

Schedule a meeting now!

Request a free ticket!